A total of 15 implants failed after replacement in 11 patients during the first 6 months of follow-up. Of these, nine failures (15.25%) occurred in seven patients (13.21%) after immediate replacement, and six (9.09%) occurred in four patients (7.02%) who underwent delayed replacement. No statistically significant differences were detected between the two groups (P = 0.431).
No significant differences in implant survival at sites of previous failure were found according to the timing of implant replacement.
No significant differences in implant survival at sites of previous failure were found according to the timing of implant replacement.In recent years, dental malpractice claims have increased dramatically worldwide. The present study aimed to categorise and analyse claims related to implant dentistry that resulted in legal decisions in Israel, seeking to contribute to dental risk management and improve patient safety.
This study analysed legal claims registered by Medical Consultants International between 2005 and 2015. Only closed cases in which a decision was made were included. The parameters studied included patient age and sex, date of the complaint, treatment setting (private/public clinic), description of the adverse event and type of negligence claimed.
The cohort included 709 settled claims out of a total of 1066 that were litigated against dental practitioners in Israel during the study period. Of the patients included, 60.0% were women and 63.9% were aged 40 to 59 years. The most common treatment-related damage was neural injury in 133 patients (18.7% of the cohort). Unplanned changes in the treatment plan and violation of autonomy were the most frequent documentation-/information-related claims (66.3% and 32.7%, respectively). The legal responsibility of the dental practitioner was acknowledged in 89.0% of cases. Dental practitioners working in the private sector were more likely to be sued due to violation of autonomy than those working in public clinics.
Although the main cause for lawsuits was actual bodily injury, the high percentage of documentation-/information-related malpractice claims calls for increased awareness of patients' autonomy and rights. Practitioners should dedicate a significant part of the entire treatment time to preoperative diagnosis and planning.
Although the main cause for lawsuits was actual bodily injury, the high percentage of documentation-/information-related malpractice claims calls for increased awareness of patients' autonomy and rights. Practitioners should dedicate a significant part of the entire treatment time to preoperative diagnosis and planning.To evaluate short-term clinical and radiographic outcomes of bone regeneration procedures using thin cortical porcine xenogeneic bone plates in combination with autogenous bone chips compared with thin autogenous cortical plates and autogenous bone chips.
A total of 19 patients (12 women and 7 men, mean age 58.24 ± 3.09 years) were randomly allocated to two different groups regarding surgical procedure autogenous cortical plates (ACP group) and xenogeneic cortical plates (XCP group). Preoperative CBCT scans were performed for each patient. Surgical time and postoperative pain were recorded, as well as tissue healing and graft resorption after 4 months, then another surgical procedure was performed to place dental implants. Data were analysed using an analysis of covariance.
Twenty-one surgical procedures were performed on 19 patients (10 from the XCP group and 9 from the ACP group). The operative time was significantly lower in the XCP group (25.45 ± 3.88 minutes) than in the ACP group (44.10 ± 3.60 minequired significantly less operative time compared to the ACP group.Guided bone regeneration is a frequently used surgical procedure for hard tissue reconstruction when horizontal and or/vertical augmentation are needed. The treatment concept is based on the application of occlusive membranes like non-resorbable membranes or titanium mesh plus resorbable membranes. However, there are no studies comparing the microcomputed tomography results for bone obtained using these two procedures, and this was the purpose of the present study.
A total of 40 patients with vertical posterior bone mandibular atrophy were randomly assigned to group A (guided bone regeneration with titanium-reinforced polytetrafluoroethylene membrane and simultaneous implant placement) or group B (guided bone regeneration with titanium mesh and collagen membrane and simultaneous implant placement). Tissue biopsy specimens were obtained from augmented sites after 9 months for microcomputed tomography analysis of volume of interest. Bone volume (BV/TV), biomaterial volume (MatV/TV), soft tissue volume (StV/hitecture. Native bone influences the quality and microarchitecture of the obtained bone, irrespective of the technique used.
Based on microcomputed tomography analysis, both surgical approaches facilitated the obtention of approximately 30% of newly formed bone with the same microarchitecture. Native bone influences the quality and microarchitecture of the obtained bone, irrespective of the technique used.To update an existing systematic review assessing the clinical performance of full-arch implant-supported monolithic zirconia fixed dental prostheses.
The review was conducted according to the guidelines outlined in the Preferred Reporting Items of Systematic Reviews and Meta-analyses (PRISMA) statement. An electronic search was conducted using the PubMed, Science Direct and Cochrane Library databases to identify clinical studies on full-arch implant-supported monolithic and minimally layered zirconia fixed dental prostheses. Human studies with a mean follow-up of at least 1 year and published in an English-language peer-reviewed journal up to April 2020 were included. https://www.selleckchem.com/products/pifithrin-alpha.html Two independent examiners conducted the search and the review process.
The search generated 2110 articles. Thirty-three qualifying studies were retrieved for full-text evaluation and a total of 17 studies were included on the basis of preestablished criteria. All 17 studies reported satisfactory clinical and aesthetic outcomes. The technical complication rate related to this type of prosthesis is still minimal and survival rates are high.